HIL Test Bench Control Center

HIGH VOLTAGE TEST EQUIPMENT - LOCKOUT/TAGOUT REQUIRED

Safety Interlock System

System Status

Main Contactor OPEN
Pre-charge Circuit READY
Ground Fault Monitor CLEAR
Isolation Monitor > 10 MΩ
Thermal Status 65°C
DC Link Voltage 48 V

Press to Emergency Stop

CAN Bus Monitor

[12:34:56.789] 0x230 DAB_CMD: phase=30deg freq=50kHz
[12:34:56.790] 0x231 DAB_STATUS: zvs=OK i_circ=2.3A
[12:34:56.791] 0x232 MFT_THERM: tj_pri=65C tj_sec=58C t_core=72C
[12:34:56.792] 0x240 DCLINK: v_dc=48.2V i_dc=125A
[12:34:56.793] 0x250 GRID_SYNC: f=60.00Hz v_rms=480V pf=0.98
[12:34:56.794] 0x260 PROTECTION: status=OK faults=0x0000
[12:34:56.795] 0x270 EFFICIENCY: eta=98.2% p_loss=2.8kW

Automated Test Sequences

Power Cycling Test

Pre-charge DC link capacitors ✓ Complete
Enable gate drivers ✓ Complete
Ramp to 50% load Running...
Thermal cycling (100 cycles) Pending
Efficiency measurement Pending

Real-Time Telemetry